Range Of Motion Measurement Knee Goniometer

Validity and reliability of using photography for measuring knee ...

Background: The clinimetric properties of knee goniometry are essential to appreciate in light of its extensive use in the orthopaedic and rehabilitative communities. Intra-observer reliability is thought to be satisfactory, but the validity and inter-rater reliability of knee goniometry often demonstrate unacceptable levels of variation. This study tests the validity and reliability of measuring knee range of motion using goniometry and photographic records. Methods: Design: Methodology study assessing the validity and reliability of one method (`Marker Method`) which uses a skin marker over the greater trochanter and another method (`Line of Femur Method`) which requires estimation of the line of femur. Setting: Radiology and orthopaedic departments of two teaching hospitals. Participants: 31 volunteers (13 arthritic and 18 healthy subjects). Knee range of motion was measured radiographically and photographically using a goniometer. Three assessors were assessed for reliability and validity. Main outcomes: Agreement between methods and within raters was assessed using concordance correlation coefficient (CCCs). Agreement between raters was assessed using intra-class correlation coefficients (ICCs). 95% limits of agreement for the mean difference for all paired comparisons were computed. Results: Validity (referenced to radiographs): Each method for all 3 raters yielded very high CCCs for flexion (0.975 to 0.988), and moderate to substantial CCCs for extension angles (0.478 to 0.678). The mean differences and 95% limits of agreement were narrower for flexion than they were for extension. Intra-rater reliability: For flexion and extension, very high CCCs were attained for all 3 raters for both methods with slightly greater CCCs seen for flexion (CCCs varied from 0.981 to 0.998). Inter-rater reliability: For both methods, very high ICCs (min to max: 0.891 to 0.995) were obtained for flexion and extension. Slightly higher coefficients were obtained for flexion compared to extension, and with the Marker compared to the Line of Femur Method. For intra- and inter-rater reliability, the mean differences (within 2 degrees) and 95% limits of agreement (within 5 degrees) were generally clinically acceptable for both methods.


Range Of Motion Measurement Knee Goniometer - Bookshelf

Joint Range of Motion and Muscle Length Testing

Joint Range of Motion and Muscle Length Testing

INTRARATER RELIABILITY: KNEE RANGE OF MOTION AROM, Active range of motion; ... supine for knee measurement, but the distal arm of the goniometer was aligned ...

Examination of musculoskeletal injuries

Examination of musculoskeletal injuries

To correctly align the goniometer arms, position yourself so your line of vision is at the ... See “Range of Motion Measurement Technique” for a summary. ...

A Physiotherapist's Guide to Clinical Measurement

A Physiotherapist's Guide to Clinical Measurement

GONIOMETRIC MEASUREMENT To assess the range of motion (ROM) of a patient's peripheral joint, a clinician will generally use a universal goniometer (Fig. ...

The effects of hip musculature on knee valgus during a squat task with and without a 2-inch heel block

The effects of hip musculature on knee valgus during a squat task with and without a 2-inch heel block

For both range of motion measurements, the subjects will be in a supine position . ... The axis of the goniometer will be placed over the inferior pole of ...

Joint motion and function assessment, a research-based practical guide

Joint motion and function assessment, a research-based practical guide

Larger goniometers are usually used for measurement of joint range at ... measurements compared to goniometric measurements of knee joint position (26), ...

Day-to-day Knowledge Directory


Reliability of Digital Compass Goniometer in Knee Joint Range ...
goniometer combined with inclinometer with standard range of motion ... Results: Range of motion of knee joint measured by DCG correlated very well with the data ...

Goniometer - Wikipedia, the free encyclopedia
[edit] Light measurement. Goniophotometers measure the spatial distribution of light ... knee or elbow), the therapist can use a goniometer to assess what the range of motion is ...

Meaning Of Range Of Motion Measurements | LIVESTRONG.COM
Meaning Of Range Of Motion Measurements. Range of motion ROM measurements determine the amount of movement that you have within each joint. It can also indicate the ...

Range of Motion | Human Evaluation from Lafayette Instrument ...
Range of Motion: Whether you are looking to test the smallest finger joint or measure the motion of an elbow or knee, we have the products you are looking for right here.

Joint Range of Motion Data Using a Goniometer
Joint flexibility is defined as the range of motion (ROM) allowed at a joint. ... anatomical landmarks are well defined, the accuracy of measurement is ...